Brand Name : GENY
Model Number : SZ03A-K6
Certification : ISO, CE
Place of Origin : China
MOQ : 1
Price : negotiate rates
Payment Terms : T/T, L/C, D/P, T/T
Supply Ability : 2 sets/ 3 months
Delivery Time : 6~8weeks
Packaging Details : Plywood cases
Test Voltage Range : 30V – 480V
Test Current Range : 10mA – 120A
Phase Angle : 0º – 360º
Test Frequency : 45Hz – 65Hz
Voltage Supply : 220V ± 10%, 50/60Hz ± 2Hz
Relative Humidity : 45% -- 75%
| SZ03A-K6 | |
| Test Voltage | |
| Range | 30V – 480V | 
| Error | ±0.05% (30V – 480V) ±0.1% (5V – 50V) | 
| Display range | 5.000000V – 480.0000V | 
| Test Current | |
| Range | 10mA – 120A | 
| Error | ±0.05% (0.2A – 120A) ±0.1% (10mA – 0.2A) | 
| Display range | 1.000000mA-120.0000A | 
| Power measure error | |
| Active power | ±0.05% (0.2A – 120A) | 
| Reactive power | ±0.1% (0.2A – 120A) | 
| Apparent power | ±0.1% (0.2A – 120A) | 
| Energy measure error | |
| Active energy | -- | 
| Reactive energy | -- | 
| Apparent energy | -- | 
| Phase angle | |
| Range | 0º – 360º | 
| Error | ±0.05º | 
| Display range | 0.000001º -- 359.9999º | 
| Frequency | |
| Range | 45Hz – 65Hz | 
| Display range | 45.0000 – 65.0000 | 
| Pulse output | |
| High frequency output(CH) | 1×109 (0.2A – 1A) 1×108 (1A – 10A) 1×107 (10A – 120A) | 
| Low frequency output(CL) | 2×10-5×CH | 
| Pulse ratio | 1:1 | 
| Output level | 5V | 
| Pulse input | |
| Input level | -- | 
| Input frequency | -- | 
| Other | |
| Voltage Supply | 220V ± 10%, 50/60Hz ± 2Hz | 
| Ambient temperature | 10°C -- 30°C | 
| Influence of external fields | ≤ 0.05 % / mT | 
| Relative humidity | 45% -- 75% | 
| Dimensions (W×H×D) (mm) | 432×131×308 | 
| Weight (kg) | 15 | 
This is wide current range Three Phase Reference Standard Meter, suit for Stationary Three Phase Energy Meter Test System.
1. High accuracy up to 0.05%
2. Testing type: 3 phase 4 wire, 3 phase 3 wire
3. Testing mode: active power, reactive power, cross connection reactive power
4. Measuring voltage, current, phase, frequency, power etc of each phase
5. Measuring phase angle of phase to phase, sum of active power, sum of reactive power etc
6. Test data can be managed by computer via Rs232 interface


|   | 
| 3ph Reference Standard Meter 10Ma – 120A Calibration Of Electrical Test Equipment Images | 
 Sz-03A-K6 Electrical Test Meter Calibration Stationary Three Phase Energy Meter
                                                                                    
                        
                        
                        
                                                            Sz-03A-K6 Electrical Test Meter Calibration Stationary Three Phase Energy Meter
                                                    
                        
                     Sz-03A-K6 Calibration Electrical Testers GENY Energy Meter Calibration Equipment
                                                                                    
                        
                        
                        
                                                            Sz-03A-K6 Calibration Electrical Testers GENY Energy Meter Calibration Equipment
                                                    
                        
                     Sz-03A-K6 Three Phase Stationary Reference Standard Meter Customized
                                                                                    
                        
                        
                        
                                                            Sz-03A-K6 Three Phase Stationary Reference Standard Meter Customized
                                                    
                        
                     3 Phase 3 Wire Energy Meter SZ-03A-K8 Test Meter Calibration
                                                                                    
                        
                        
                        
                                                            3 Phase 3 Wire Energy Meter SZ-03A-K8 Test Meter Calibration
                                                    
                        
                     Three Phase Multi Meter Calibration SZ-03A-K8 Reference Standard Meter
                                                                                    
                        
                        
                        
                                                            Three Phase Multi Meter Calibration SZ-03A-K8 Reference Standard Meter
                                                    
                        
                     Reference Electrical Test Meter Calibration 1ma - 120A Electrical Tester
                                                                                    
                        
                        
                        
                                                            Reference Electrical Test Meter Calibration 1ma - 120A Electrical Tester
                                                    
                        
                     SZ-03A-K8 Stationary Reference Standard - Advanced Electric Parameter Measuremen
                                                                                    
                        
                        
                        
                                                            SZ-03A-K8 Stationary Reference Standard - Advanced Electric Parameter Measuremen
                                                    
                        
                     Prepayment Electrical Meter Calibration Sz-03A-K8 With Terminal Connection
                                                                                    
                        
                        
                        
                                                            Prepayment Electrical Meter Calibration Sz-03A-K8 With Terminal Connection
                                                    
                        
                     3 Phase 4 Wire Stationary Reference Standard Accuracy 0.02% Test Meter
                                                                                    
                        
                        
                        
                                                            3 Phase 4 Wire Stationary Reference Standard Accuracy 0.02% Test Meter
                                                    
                        
                     0.02% Accuracy Electrical Tester Calibration SZ-03A-K8 Watt Hour Meter
                                                                                    
                        
                        
                        
                                                            0.02% Accuracy Electrical Tester Calibration SZ-03A-K8 Watt Hour Meter